Thermocouple compensation wire cables type
Equivalent use: IEC584-3 "Thermocouple Part III - compensation wire" international standards, product quality is better than B4989-85 "thermocouple with compensation wire" national standards. Insulation layer and the use of imported high-quality fluorine plastic sheath, and the use of the overall continuous extrusion of new technology, the product has excellent acid, alkali, wear-resistant and non-combustible extension of the performance can be immersed in water long-term use. The use of temperature at -60 ~ 205 ~ 260 ℃, belonging to the contemporary international advanced level. Model and name:
Compensating wire type according to product variety is divided into: SC, KC, KX, EX, JX, TX.
Wherein: a) the first letter of the model corresponds to the index number of the thermocouple;
B) The letter "X" indicates the extension type compensation wire (type)
C) The letter "C" indicates the compensation type compensation wire (type)
Note: SC-type compensation wire can be equipped with R-type thermocouple number.
Use classification, permission level, sheath coloring mark:
Use classification | Logo | Allow registration and sheath coloring | |
Normal level | Precision level | ||
General use | G | (black) | S(gray) |
Heat resistance | H | (black) | S(gray) |
Structural characteristics, insulating layer, sheathing material, operating temperature
Insulation and protective layer | Operating temperature | |
Material | symbol | |
Polyfluoroethylene | PVC | -25~70℃ -25~105℃ |
FEP | FEP | -60~205℃ |
Soluble polytetrafluoroethylene | PFA | -60~260℃ |
Product labeling (marking)
Equipped with thermoelectric Even degree number | General use (G) Product labeling | Heat-resistant (H) Product labeling | ||
Ordinary level | Precision (S) | Ordinary level | Precision (S) | |
S | SC-G | SC-GS | SC-H | -- |
N | NC-G | NC-GS | NC-H | NC-HS |
K | NC-G | NC-GS | NC-H | -- |
KC2-G | KG2-GS | KC2-H | KC2-HS | |
KX-G | KX-GS | KX-H | KX-HS | |
E | EX-G | EX-GS | EX-H | EX-HS |
J | JX-G | JX-GS | JX-H | JX-HS |
T | TX-G | TX-GS | TX-H | TX-HS |
Compensating wire alloy wire and insulating layer color
Compensation number wires models | With the thermocouple of the sub-degree | Compensation wire alloy wire | Insulating layer coloring | ||
positive electrode | negative electrode | positive electrode | negative electrode | ||
SC | S(Platinum rhodium 10-platinum) | SPC(Copper) | SNC(Nickel chromium) | red | green |
NC | N(Nickel chromium silicon - nickel silicon) | NPC(Iron) | NNC(Nickel chromium) | red | yellow |
KC | K(Copper - constantan) | KPC(Copper) | KNC(Nickel chromium) | red | blue |
KX | K(Nickel chromium - nickel silicon) | KPX(Nickel chromium) | KNX(Nickel chromium) | red | black |
EX | E(Nickel chromium - copper nickel) | EPX(Nickel chromium) | ENX(Nickel chromium) | red | Brown |
JX | J(Iron - copper nickel) | JPX(Iron) | JNX(Nickel chromium) | red | purple |
TX | T(Copper-copper-nickel) | TPX(Copper) | TNX(Nickel chromium) | red | White |
1, the compensation cable by product variety is divided into: SC BC KC KX JX TX EA, where the
letter "×" that extended compensation wire, letters
"C" means the compensating cable whose thermoelectric potential and resistance value conform to the
following table:
2, compensation cable insulation test insulation resistance at 40 ℃ water after 24 hours is not
less than (10 meters) 25MΩ.
3, the compensation cable heat aging 24 hours after 5 times the diameter test, the voltage test
5000V / 1min does not breakdown.

Add: No. 16, Road 3, Sanjiang Industry Zone, Shengzhou, Zhejiang, China
Contact:Eric Xie
Email: sale@benoelectric.com
Mob: +861598895936
Skype: ericxie123@outlook.com
Wechat & Whatsapp: +8615988295936